Thermal Inspection of a 199.875 kW Rooftop Solar Plant

Drone-based thermal and RGB inspection of a rooftop photovoltaic plant in Italy, covering 975 modules to identify thermal anomalies, visible module damage, and conditions affecting plant performance and maintenance priorities.

Rooftop199.875 kWThermal + RGBIEC 62446-⁠3 Compliant Thermographic InspectionItaly2026-08

Hakan Yaralı · Accredited Technical Manager

Aerial view of rooftop solar modules with brown burn marks on several cells above a rusted metal roof

Project at a Glance

Plant capacity
199.875 kW
Modules inspected
975
Inspection area
~0.286 ha
Data captured
Thermal + RGB
Inspection duration
1 field day
Suspected anomalies
342
Location
Italy
Inspection date
2026-08
Inspection standard
IEC 62446-⁠3 Compliant Thermographic Inspection

Project Context

Visible burn marks and surface damage were identified on several PV modules during the inspection. These affected areas were associated with abnormal thermal behavior, particularly cell and hotspot anomalies, indicating localized heating and reduced module performance. Drone-based thermal and RGB inspection allowed the visible damage to be evaluated together with its thermal impact, helping the maintenance team identify the most affected modules and prioritize corrective action.

Inspection Scope

What was inspected

  • Thermal and RGB imagery across the rooftop photovoltaic array
  • 975 photovoltaic modules included in the inspection scope
  • Assessment of visible burn marks and surface damage affecting module condition
  • Assessment of contamination and other visible conditions affecting module performance
  • AI-assisted anomaly screening at module level
  • Detection and classification of open circuit string, cell, hotspot, multicell, multi-hotspot, diode, junction box, open circuit module, and short circuit module anomalies
  • Cross-assessment of thermal findings with RGB observations
  • Technical review of identified anomalies
  • Prioritization based on estimated operational, efficiency, and financial impact

Methodology

  1. 1

    Pre-flight planning

    Flight altitude was defined to achieve a 3 cm/pixel GSD in accordance with IEC 62446-⁠3 requirements, while overlap and flight route were planned according to the plant layout.

  2. 2

    RGB and thermal data acquisition

    Thermal and RGB imagery was captured across the inspected photovoltaic array.

  3. 3

    Image quality control and alignment

    Coverage and thermal image integrity were checked and imagery was georeferenced for analysis.

  4. 4

    AI-assisted anomaly screening

    Thermal patterns were detected, grouped and mapped to individual photovoltaic modules.

  5. 5

    Technical review

    Detected findings were reviewed and classified according to their thermal characteristics.

  6. 6

    Reporting and verification plan

    Prioritized findings were delivered to the client together with efficiency and loss-impact assessments to support subsequent maintenance activities.

Findings

FindingDetected patternPossible causeVerificationStatus
Open Circuit StringElectrical continuity is interrupted, causing the entire string to become inactive.Blown fuse, damaged or disconnected cable, faulty connector, or another interruption within the string circuit.Thermal measurement and visual inspectionReported
Cell FaultA PV cell loses normal function, causing localized heating and reduced performance.Manufacturing defects, microcracks, physical damage, or deterioration of the affected cell.Thermal measurement and visual inspectionReported
HotspotA localized area reaches an abnormally high temperature compared with its surroundings.Cell damage, microcracks, physical defects, shading, contamination, or other conditions that cause abnormal localized heating.Thermal measurement and visual inspectionReported
Multicell FaultMultiple PV cells within the same module lose normal function, causing wider performance and power loss.Manufacturing defects, thermal stress, or physical damage affecting multiple cells within the module.Thermal measurement and visual inspectionReported
Multi HotspotMultiple localized areas within the same module reach abnormally high temperatures.Multiple cell defects, microcracks, physical damage, contamination, or localized electrical resistance.Thermal measurement and visual inspectionReported
Diode FaultUniform heating across a module substring indicates that the affected cell group is being bypassed.Bypass diode short circuit or continuous conduction, causing current to bypass the affected substring.Thermal measurement and visual inspectionReported
Junction BoxLocalized heating is concentrated around the module junction box area.Loose or resistive connections, internal junction box damage, or component-related electrical stress.Thermal measurement and visual inspectionReported
Open Circuit ModuleCurrent flow through the module is interrupted, preventing the module from operating normally.Internal connection failure, damaged conductors, connector faults, or interruption within the module circuit.Thermal measurement and visual inspectionReported
Short Circuit ModuleAbnormal heating across the module indicates unintended current flow within the internal circuit.An unintended conductive path between positive and negative poles, causing short-circuit behavior within the string.Thermal measurement and visual inspectionReported

Thermal Evidence

Thermal image

Thermal image of rooftop solar modules in a purple palette with many bright yellow hotspots on individual cells

RGB image

Aerial view of rooftop solar modules with brown burn marks on several cells above a rusted metal roof
Thermal and RGB views of the 199.875 kW rooftop plant in Italy, showing visible burn marks on modules and the localized heating associated with them. Visible RGB findings that coincide with thermal anomalies provide useful diagnostic context but should not automatically be considered the confirmed cause. Additional field verification may be required to establish the underlying root cause.

Actions and Outcome

  • A total of 342 faulty panels were identified and reported to the client.
  • Visible burn marks and surface damage were observed on affected modules and were associated with a high occurrence of cell and hotspot anomalies.
  • Thermal analysis identified 136 open circuit string, 104 cell fault, and 95 hotspot findings, showing that the most affected areas were concentrated around modules with visible damage and contamination-related conditions.
  • Modules showing both visible damage and abnormal thermal behavior were prioritized for maintenance review.
  • Findings were prioritized according to their estimated impact on plant efficiency, energy production, and financial loss.

Limitations

Thermal imagery can identify temperature patterns requiring investigation, but it does not independently confirm every electrical or mechanical root cause. Irradiance, wind, reflections, shading, soiling, flight conditions and equipment configuration may affect interpretation.

Other case studies

Aerial view of rooftop solar rows on a metal roof with one displaced module resting on the array

Thermal Inspection of a 3.60 MW Rooftop Solar Plant

Drone-based thermal and RGB inspection of a rooftop photovoltaic plant in Türkiye, covering 12,703 modules to identify thermal anomalies, physical module issues, and conditions affecting plant performance and maintenance priorities.

3,601.4 kWThermal + RGBIEC 62446-⁠3 Compliant Thermographic Inspection
Aerial view of a rooftop solar array with visible cracking on many photovoltaic modules

Thermal Inspection of an 827.48 kW Solar Plant

Drone-based thermal and RGB inspection of a photovoltaic plant in Italy, covering 1,948 modules to identify thermal anomalies associated with visible module damage and support performance assessment and maintenance prioritization.

827.48 kWThermal + RGBIEC 62446-⁠3 Compliant Thermographic Inspection

Planning a photovoltaic inspection?

Share your plant capacity, module count and inspection objective to receive a proposed inspection scope.

Request an Inspection Scope